How to reduce noise interference during elevator air conditioning operation?

Publish Time: 2025-06-12
The noise interference generated by elevator air conditioning during operation will affect the elevator experience and may even cause trouble to the surrounding environment. Therefore, reducing noise requires comprehensive measures from multiple aspects such as equipment selection, installation process, and structural design. The generation of noise is often related to factors such as mechanical vibration, air flow, and component friction. Only by accurately locating the noise source and taking targeted measures can the noise level be effectively controlled and a quiet elevator environment be created.

The noise reduction design of the core components of the equipment is the foundation. The compressor and fan of the elevator air conditioning are the main noise sources. The mechanical vibration of the compressor during operation will be transmitted to the elevator structure through the fuselage, and the friction between the fan and the air will also generate noise when it rotates. When selecting, models equipped with silent compressors can be given priority. Such compressors usually adopt a vortex or rotor design, which is smoother and has a smaller vibration amplitude than piston compressors. In terms of fans, the use of low-speed centrifugal fans or axial flow fans and the optimization of the curvature and spacing of the blades can reduce the noise generated by air turbulence. At the same time, if the fan impeller is wrapped with sound insulation material, it can further block the spread of noise.

The vibration reduction treatment of the installation link is crucial. If there is no shock-absorbing measure for the installation of elevator air conditioning, the vibration of the equipment during operation will be transmitted to the elevator car or shaft through the bracket, bolts and other parts, forming structural noise. The correct approach is to install a rubber shock-absorbing pad between the air conditioner main unit and the mounting bracket. This material has good elasticity and can absorb most of the vibration energy to avoid noise transmission caused by rigid connection. For the copper pipes connecting the indoor and outdoor units of the air conditioner, they need to be fixed with elastic pipe clamps to prevent the pipes from shaking and rubbing due to air flow impact or mechanical vibration. At the same time, sound insulation cotton is filled at the contact point between the pipe and the wall to block the vibration transmission path.

Optimization of the air duct system can reduce air noise. If the air outlet and return air outlet of the elevator air conditioning are not designed reasonably, "whooshing" wind noise will be generated when the air flow passes quickly, especially when the wind speed is high. The airflow can be diverted by expanding the air outlet area and installing guide blades to make the air flow more uniform and reduce the turbulence intensity. A soundproof filter is installed at the return air outlet, which can not only filter air impurities but also absorb some wind noise. In addition, sound-absorbing materials such as centrifugal glass wool or sound-absorbing sponge are pasted on the inner wall of the air duct to absorb sound energy with its porous structure, reducing the reflection and propagation of noise in the air duct.

The sound insulation treatment of the car and the shaft cannot be ignored. When the elevator air conditioning is running, the noise will be transmitted to the outside space through the gap of the car or the shaft structure. Therefore, it is necessary to strengthen the sealing of the car and the sound insulation performance of the shaft. Soundproof felt is laid at the contact point between the top of the car and the air conditioning installation part. This material has high density and good sound insulation effect, which can block the transmission of equipment noise into the car. Soundproof boards can be installed on the inner wall of the shaft. The boards are made of materials with both sound insulation and fireproof properties, such as gypsum board composite sound insulation cotton. At the same time, the gaps in the shaft are filled to reduce the reflection and superposition of noise in the shaft and reduce the impact on adjacent floors.

Intelligent adjustment of the control system assists in noise reduction. If the elevator air conditioning is in a high-load operation state for a long time, the equipment noise will also increase accordingly. This situation can be effectively improved by optimizing the operation mode through the intelligent control system. For example, the automatic frequency conversion function is set. When the temperature in the car is close to the set value, the system automatically reduces the operating power of the compressor and the fan, reducing mechanical vibration and air flow noise while maintaining a comfortable temperature. A noise monitoring module can also be added. When the noise exceeds the threshold, the system automatically adjusts the operating parameters to avoid the increase in noise caused by equipment abnormalities and achieve dynamic noise reduction.

Daily maintenance is the key to continuous noise reduction. After the elevator air conditioning has been running for a long time, the components may produce additional noise due to wear or looseness. Regular inspection and maintenance can eliminate hidden dangers in time. For example, tighten the mounting bolts of the compressor and fan to prevent loose components from causing vibration noise; clean the dust and debris in the fan impeller and air duct to avoid dynamic imbalance and poor airflow caused by dust accumulation; check whether the shock pad is aging and ineffective, and replace the parts that have lost elasticity in time. In addition, the air conditioning system is fully debugged to ensure that all components are in good operating condition and reduce the possibility of noise generation from the root.

Reducing the operating noise of elevator air conditioning requires full control of the entire process from design, installation to maintenance. Only through the silent optimization of core components, scientific shock absorption treatment, reasonable air duct design and perfect sound insulation measures, combined with intelligent control and daily maintenance, can a comprehensive noise reduction system be built. This can not only improve the comfort of the elevator environment, but also reduce the impact of equipment noise on the surrounding area, achieving dual optimization of function and experience.
×